{"product_id":"renson-healthbox-3-0-ventilacija","title":"Renson Healthbox 3.0 fan unit","description":"\u003ch6 style=\"text-align: center;\"\u003eDescription\u003c\/h6\u003e\n\u003cp\u003eRenson Healthbox® 3.0 is the smart and quiet solution for healthy indoor air. Are you planning to build or renovate? Are you dreaming of owning your own house or apartment? Then you definitely need a Healthbox® 3.0 ventilation system. The Healthbox® 3.0 demand-controlled ventilation system is a quiet and energy-efficient solution. And thanks to the various configuration options, you can take full advantage of the energy efficiency benefits for all types of homes.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch6 style=\"text-align: center;\"\u003eTechnical specifications\u003c\/h6\u003e\n\u003cdiv class=\"spp-table\"\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eType of ventilation\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eControlled mechanical exhaust ventilation\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003e(Max.) Ventilation flow rate\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e475 m3\/h (at 135 Pa)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e430 m3\/h (at 200 Pa)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eFan specifications: see technical drawings\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003ePower supply voltage\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e230 VAC ± 10% (50 Hz, 60 Hz)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003ePower cord included (length: ± 2 m)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eRated capacity of the ventilation unit\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eMaximum flow rate 150 m3\/h\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e28 watts\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eMaximum flow rate 225 m3\/h\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e35 watts\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eMaximum flow rate 325 m3\/h\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e53 watts\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eMaximum flow rate 400 m3\/h\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e80 watts\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eMaximum flow rate 475 m3\/h\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e85 watts\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003eSee graphs\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eDimensions\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eVentilation unit without control valves\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e390 x 443 x 200 mm (LxWxH)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eVentilation unit with control valves\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e567 x 567 x 200 mm (LxWxH)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003eSee technical drawings\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eWeight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eVentilation unit without control valves\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e2600 g\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eControl valve + adapter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e240 g + 65 g\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eConnection to inlet duct\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eChoice of adapter: 80 and\/or 125 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eConnection version for extraction channel\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eChoice of adapter: 125 or 150 mm (160 mm dd. with additional ring)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eVentilation\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eExtremely quiet and energy-efficient EC motor with 180 mm dia. Impeller. Active variable pressure control: in each case, the lowest possible pressure level is set to match the required extraction flow rates.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eMaximum ventilation operating pressure\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e350 Pa\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e– Recommended operating pressure at designed flow rate: ≤ 200 Pa\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e– Target value for very efficient operating pressure at design flow rate (see TV No 258): ≤ 100 Pa\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eCalibration reading\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eUsing the user app, install the software \u0026amp; the Renson My-Lio-professional web portal\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eAutomatic calibration of ventilation flow rate (patented)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eWorks in 2 consecutive stages:\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e– Step 1: Pressure drop readings taken automatically in all ducts\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e– Step 2: Air distribution valve positions calculated automatically\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eAutomatic calibration time\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e– 2 -5 control valve calibration: up to ± 3 minutes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e– Calibration of 6 to 8 control valves: up to ± 5 minutes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e– Calibration of control valves 9 to 11: up to ± 6 minutes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table\"\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eMaximum number of extraction connection points\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eBasic forms\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e7\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eUse of valve manifold\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e11 (under a few restrictive conditions)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eValve manifold\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e1 or 2 valve manifolds to be connected to the fan unit with 1 to 3 control valves to be connected to each valve manifold.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eThe valve manifold can also be connected remotely from the fan unit.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eElectrical connection (UTP cable Cat 5e, wire gauge 24AWG, 30 metres max.).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eConnections\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e– 1 Ethernet connection\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e– 2 x USB connection (USB socket for Wi-Fi included)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e– Inputs: 3 x DIGITAL, 1 x ANALOG (0-10 V)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eSound power level (LWA) (Reference: Ecodesign)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eQmax 150m3\/h: 32 dB(A)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eQmax 225m3\/h: 34 dB(A)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eQmax 325m3\/h: 39 dB(A)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eQmax 400m3\/h: 43 dB(A)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eQmax 475m3\/h: 47dB(A)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eCooling function\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eTemporary nominal ventilation (= demand control deactivated) at times when cooling demand is determined (= \u0026gt; optimum shading factors)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Renson","offers":[{"title":"Default Title","offer_id":42403817717992,"sku":"17065","price":1289.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0607\/5416\/5992\/products\/renson-healthbox-3-gudra-ventilacija-majaelpo.lv.jpg?v=1641914458","url":"https:\/\/elpo2.com\/products\/renson-healthbox-3-0-ventilacija","provider":"Māja elpo","version":"1.0","type":"link"}